A425
TRIODO
AMPLIFICADORA DE BF
A425
Europeo
Vf=4VIf=0,065A
Vp=200VIp=2,3mA
Vg=-2,5Vri=23K
µ=25 
  
A430
TRIODO
DETECTORA Y AMPLIFIC. DE RF
A430
Europeo
Vf=4VIf=0,06A
Vp=150VIp=1,5mA
Vg=0ri=60K
µ=30 
  
A430N
TRIODO
OSCIL., DETECT. Y AMPLIF. DE BF
A430N
Europeo
Vf=4VIf=1A
Vp=200VIp=6mA
Vg=-3,5Vri=12,5K
µ=30 
  
A435
TRIODO
AMPLIFICICADORA DE RF
A435
Europeo
Vf=4VIf=0,06A
Vp=150VIp=1,4mA
Vg=0ri=70K
µ=35 
  
A440N
TRIODO
DETECTORA Y AMPLIFIC. DE BF
A440N
Europeo
Vf=4VIf=1A
Vp=200VIp=2,5mA
Vg=-1Vri=26,6K
µ=99 
  
A441
BI-REJILLA
DETECTORA Y AMPLIFICADORA
A441
Europeo
Vf=4VIf=0,08A
Vp=20VIp=2mA
VG=20V 
Vg=-1,5Vri=45K
µ=4,5 